Zero-DayОригинал на английском
Schneider Electric SCADAPack x70 Products
Русский перевод готовится и скоро появится на сайте. Пока доступен оригинал на английском.
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and
CISA Alerts··3 мин чтения
View CSAF Summary Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality. The following versions of Schneider Electric SCADAPack x70 Products are affected: SCADAPack 47x vers:all/* (CVE-2026-81861) SCADAPack 47xi vers:all/* (CVE-2026-81861) SCADAPack 47xd vers:all/* (CVE-2026-81861) SCADAPack 470R vers:all/* (CVE-2026-81861) SCADAPack 57x vers:all/* (CVE-2026-81861) SCADAPack 3xx vers:all/* (CVE-2026-81861) SCADAPack 32 vers:all/* (CVE-2026-81861) CVSS Vendor Equipment Vulnerabilities v3 6.5 Schneider Electric Schneider Electric SCADAPack x70 Products Insufficiently Protected Credentials Background Critical Infrastructure Sectors: Critical Manufacturing, Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: France Vulnerabilities Expand All + CVE-2026-81861 There is an insufficiently protected credentials vulnerability that could result in exposure of authentication information and unauthorized access to RTU functionality. View CVE Details Affected Products Schneider Electric SCADAPack x70 Products Vendor: Schneider Electric Product Version: SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R, SCADAPack 57x, SCADAPack 3xx, SCADAPack 32 Product Status: known_affected Remediations Mitigation Implement the Role-Based Access Control (RBAC) feature and follow the SCADAPack documentation sections Security Guidelines for Administrators and Working with Role-Based Access Control. RBAC is the recommended access control mechanism for SCADAPack 47x devices and should be used in place of the Secure Lock feature. The Secure Lock feature is legacy functionality retained for backward compatibility with existing deployments and should only be used where required to support legacy system requirements. Consult the SCADAPack Cybersecurity Guide, including the SCADAPack Hardening and Secured Communication sections. In addition, apply the following standard practices to reduce the risk of exploitation: Configure network segmentation to restrict access between trusted and untrusted networks. Enable and implement the RTU firewall service to restrict unauthorized access to device services and reduce the attack surface. Documentation available in RemoteConnect and SCADAPack x70 Utilities | Schneider Electric https://www.se.com/ww/en/download/document/RemoteConnect/ Mitigation Ensure setup of network segmentation to restrict access between trusted and untrusted networks and implementation of the RTU Firewall Service to restrict unauthorized access to services. Consult the SCADAPack Cybersecurity Guide, including the SCADAPack Hardening and Secured Communication sections. In addition, implement all best practices referenced in the SCADAPack Cybersecurity Guide. Documentation available in RemoteConnect and SCADAPack x70 Utilities | Schneider Electric https://www.se.com/ww/en/download/document/RemoteConnect/ Mitigation For more information see the associated Schneider Electric security advisory SEVD-2026-251-03 Insufficiently Protected Credentials vulnerability on SCADAPack x70 Products PDF Version, CSAF Version. Relevant CWE: CWE-522 Insufficiently Protected Credentials Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N Acknowledgments Abhinav Agarwal reported this vulnerability to CISA. General Security Recommendations Schneider Electric strongly recommends the following industry cybersecurity best practices: Locate control and safety system networks and remote devices behind firewalls and isolate them from the business network. Install physic