СкамыОригинал на английском
Siemens ROS#
Русский перевод готовится и скоро появится на сайте. Пока доступен оригинал на английском.
View CSAF Summary ROS# before version 2.3.1 contains a code injection vulnerability that could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program. Siemens has released a new version for ROS# and
CISA Alerts··3 мин чтения
View CSAF Summary ROS# before version 2.3.1 contains a code injection vulnerability that could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program. Siemens has released a new version for ROS# and recommends to update to the latest version. The following versions of Siemens ROS# are affected: ROS# vers:intdot/<2.3.1 (CVE-2026-109097) CVSS Vendor Equipment v3 8.2 Siemens ROS# 1 Vulnerability Improper Control of Generation of Code ('Code Injection') Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-109097 Affected systems do not properly escape text of message definition files. This could allow an attacker that is able to pass a crafted message definition file to the user to inject arbitrary code into the generated program. Read More 1 Affected Product ROS# < V2.3.1 Product Status: known_affected Remediations Vendor fix Update to V2.3.1 or later version Additional Metrics Relevant CWE: CWE-94 Improper Control of Generation of Code ('Code Injection') CVSS Version Base Score Base Severity Vector String 3.1 8.2 HIGH CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:H/I:H/A:H View CVE Details Acknowledgments Siemens ProductCERT reported this vulnerability to CISA. General Recommendations As a general security measure, Siemens strongly recommends to protect network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends to configure the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and to follow the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Recommended Practices CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B--Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. Advisory Conversion Disclaimer This ICSA is a verbatim republication of Siemens ProductCERT SSA-435267 from a direct