СкамыОригинал на английском
Siemens SIMATIC
Русский перевод готовится и скоро появится на сайте. Пока доступен оригинал на английском.
View CSAF Summary The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recommen
CISA Alerts··3 мин чтения
View CSAF Summary The products listed below contain an authentication bypass vulnerability that could allow an on-path attacker to take over the session of a legitimate user and execute arbitrary code with the privileges of the victim user. Siemens is preparing fixes and recommends specific mitigations for products where fixes are not or not yet available. The following versions of Siemens SIMATIC are affected: SIMATIC BATCH V9.1 vers:all/* (CVE-2026-58114) SIMATIC Information Server 2020 vers:all/* (CVE-2026-58114) SIMATIC Information Server 2022 vers:all/* (CVE-2026-58114) SIMATIC PCS 7 V9.1 vers:all/* (CVE-2026-58114) SIMATIC Process Historian 2020 vers:all/* (CVE-2026-58114) SIMATIC Process Historian 2022 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V17 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V18 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V19 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V20 vers:all/* (CVE-2026-58114) SIMATIC WinCC Runtime Professional V21 vers:all/* (CVE-2026-58114) SIMATIC WinCC V7.5 vers:all/* (CVE-2026-58114) SIMATIC WinCC V8.0 vers:all/* (CVE-2026-58114) SIMATIC WinCC V8.1 vers:all/* (CVE-2026-58114) CVSS Vendor Equipment v3 7.5 Siemens SIMATIC BATCH V9.1 1 Vulnerability Weak Authentication Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities CVE-2026-58114 Affected systems do not properly secure their remote user authentication with the deprecated NTLM protocol. This could allow unauthenticated remote attackers, who have achieved a machine in the middle position, to relay NTLM authentication and impersonate a legitimate user. The potential impact depends on the services that are accessible, e.g. a SQL server used by WinCC. Read More 14 Affected Products SIMATIC BATCH V9.1 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix planned Currently no fix is planned SIMATIC WinCC Runtime Professional V20 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC Runtime Professional V21 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC V7.5 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC V8.0 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC WinCC V8.1 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID None available Currently no fix is available SIMATIC Information Server 2020 Product Status: known_affected Remediations Mitigation Customers can manually configure the SQL Server Database for encrypting communication as described in https://support.industry.siemens.com/cs/mdm/109818202?c=145291786635&lc=en-ID No fix p