Zero-DayОригинал на английском
ABB Protection and Control IED Manager PCM600
Русский перевод готовится и скоро появится на сайте. Пока доступен оригинал на английском.
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges or overwrite files. The following versions of ABB Protection and Control IED Manager PCM600 are affected: Protection and Control IED Manager PCM600 <=2.14 (CVE-2026-1
CISA Alerts··4 мин чтения
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges or overwrite files. The following versions of ABB Protection and Control IED Manager PCM600 are affected: Protection and Control IED Manager PCM600 <=2.14 (CVE-2026-15952, CVE-2026-15953) CVSS Vendor Equipment Vulnerabilities v3 6.4 ABB ABB Protection and Control IED Manager PCM600 Incorrect Permission Assignment for Critical Resource, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-15952 A vulnerability exists in the Scheduler Service installed with PCM600. The service executes under the LocalSystem account while permissions are granted to standard PCM600 users through membership in the local users group. An attacker with local access and valid user credentials may exploit this vulnerability to elevate privileges and obtain control of the affected host. View CVE Details Affected Products ABB Protection and Control IED Manager PCM600 Vendor: ABB Product Version: ABB Protection and Control IED Manager PCM600: <=2.14 Product Status: known_affected Remediations Mitigation ABB recommends the following workaround. Although this workaround does not correct the underlying vulnerability, it reduces the risk of privilege escalation. Mitigation Configure the appropriate ABBPCMSchedulerService instance to run using the same Windows account that is used to operate PCM600: Open Services.msc. Locate the ABBPCMSchedulerService corresponding to the installed PCM600 version. Open Properties and select the Log On tab. The service should be configured to log on with the same Windows user account that is used for the PCM600 application. Ensure that this account has the required "Log on as a service" privilege. Mitigation When authentication is enabled for the IED, the Scheduler tool must be used with the same Windows account configured as the Scheduler Service logon account. Mitigation For installations using IED security certificates, the PCM600 setting Always trust IED security certifcates must be enabled only when PCM600-to-IED communication takes place in a secure and trusted environment. Mitigation For more information, see ABB security advisory 2NGA003170 and 2NGA003179. Relevant CWE: CWE-732 Incorrect Permission Assignment for Critical Resource Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.4 MEDIUM CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H 4.0 7.1 HIGH CVSS:4.0/AV:L/AC:H/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-15953 A vulnerability exists in the processing of PCM600 project archives files. Insufficient validation of archive entry paths may permit path traversal during extraction, potentially allowing files to be written to loca tions outside the intended extraction directory. View CVE Details Affected Products ABB Protection and Control IED Manager PCM600 Vendor: ABB Product Version: ABB Protection and Control IED Manager PCM600: <=2.14 Product Status: known_affected Remediations Mitigation Configure the appropriate ABBPCMSchedulerService instance to run using the same Windows account that is used to operate PCM600: Open Services.msc. Locate the ABBPCMSchedulerService corresponding to the installed PCM600 version. Open Properties and select the Log On tab. The service should be configured to log on with the same Windows user account that is used for the PCM600 application. Ensure that this account has the required "Log on as a service" privilege. Mitigation When authentication is enabled for the IED, the Scheduler tool must be used with the same Windows account configured as the Scheduler Service logon account. Mitigation For installations using IED security certificates, the PCM600 setting Always trust IED security certifcates must be enabled only when PCM600-to-IED communication takes place in