СкамыОригинал на английском
Siemens Desigo DXR and PXC Controllers
Русский перевод готовится и скоро появится на сайте. Пока доступен оригинал на английском.
View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has
CISA Alerts··3 мин чтения
View CSAF Summary A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Desigo DXR and PXC Controllers are affected: Desigo DXR2 vers:intdot/<01.21.233.16-7862 (CVE-2026-59693) Desigo PXC3 vers:intdot/<01.21.233.16-7862 (CVE-2026-59693) Desigo PXC4 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC5.E003 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC5.E24 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) Desigo PXC7 vers:intdot/<02.21.194.36-2715 (CVE-2026-59693) CVSS Vendor Equipment Vulnerabilities v3 4.3 Siemens Siemens Desigo DXR and PXC Controllers Improper Check for Unusual or Exceptional Conditions Background Critical Infrastructure Sectors: Commercial Facilities, Critical Manufacturing, Energy, Healthcare and Public Health, Transportation Systems Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2026-59693 The affected devices are vulnerable to a denial-of-service (DoS) vulnerability. An attacker can exploit this issue by sending a malformed BACnet packet, causing the device to stop responding to BACnet queries. Recovery requires a device reset or reboot to restore normal functionality. View CVE Details Affected Products Siemens Desigo DXR and PXC Controllers Vendor: Siemens Product Version: Desigo DXR2 < V01.21.233.16-7862, Desigo PXC3 < V01.21.233.16-7862, Desigo PXC4 < V02.21.194.36-2715, Desigo PXC5.E003 < V02.21.194.36-2715, Desigo PXC5.E24 < V02.21.194.36-2715, Desigo PXC7 < V02.21.194.36-2715 Product Status: known_affected Remediations Vendor fix Update to V01.21.233.16-7862 or later version Please contact your local Siemens office for additional support in obtaining the update. Vendor fix Update to V02.21.194.36-2715 or later version Please contact your local Siemens office for additional support in obtaining the update. Relevant CWE: CWE-754 Improper Check for Unusual or Exceptional Conditions Metrics CVSS Version Base Score Base Severity Vector String 3.1 4.3 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L Acknowledgments Thomas EBI of Sauter reported this vulnerability to Siemens General Recommendations As a general security measure, Siemens strongly recommends protecting network access to devices with appropriate mechanisms. In order to operate the devices in a protected IT environment, Siemens recommends configuring the environment according to Siemens' operational guidelines for Industrial Security (Download: https://www.siemens.com/cert/operational-guidelines-industrial-security), and following the recommendations in the product manuals. Additional information on Industrial Security by Siemens can be found at: https://www.siemens.com/industrialsecurity Additional Resources For further inquiries on security vulnerabilities in Siemens products and solutions, please contact the Siemens ProductCERT: https://www.siemens.com/cert/advisories Terms of Use The use of Siemens Security Advisories is subject to the terms and conditions listed on: https://www.siemens.com/productcert/terms-of-use. Legal Notice and Terms of Use This product is provided subject to this Notification (https://www.cisa.gov/notification) and this Privacy & Use policy (https://www.cisa.gov/privacy-policy). Recommended Practices CISA recommends users take defensive measures to minimize the exploitation risk of these vulnerabilities. Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use more secure methods, such as virt
