Zero-Day
Hitachi Energy FACTS Control Platform (FCP)
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity and availability of the product. Following FA
CISA Alerts··3 min read
View CSAF Summary Hitachi Energy is aware of vulnerabilities that affect the FACTS Control systems with GWS component listed in this document. An attacker exploiting these vulnerabilities can cause impact on confidentiality, integrity and availability of the product. Following FACTS Control systems with GWS component deployed from year 2020 onwards are likely affected by the above vulnerabilities. Product deployments without GWS component are not affected. • SVC Light (STATCOM) • Fixed Series Capacitor • Thyristor Controlled Series Capacitor • Static Var Compensator • Static Watt Compensator • Hybrid Synchronous Condensers Please refer to the Recommended Immediate Actions for information about the mitigation/remediation. The affected FCP versions are only applicable if GWS component is present. The following versions of Hitachi Energy FACTS Control Platform (FCP) are affected: FACTS Control Platform (FCP) 3.4.0, 3.7.0, 3.8.0, 3.10.0, 3.12.0, 3.14.0, 3.15.0, 4.0.0, 4.0.1, 4.1.0, 4.1.1 (CVE-2024-4872, CVE-2024-3980, CVE-2024-3982, CVE-2024-7940, CVE-2024-7941) CVSS Vendor Equipment Vulnerabilities v3 9.9 Hitachi Energy Hitachi Energy FACTS Control Platform (FCP) Improper Neutralization of Special Elements in Data Query Logic, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Authentication Bypass by Capture-replay, Missing Authentication for Critical Function, URL Redirection to Untrusted Site ('Open Redirect') Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2024-4872 A vulnerability exists in the query validation of the FACTS Control system with GWS component. If exploited this could allow an authenticated attacker to inject code towards persistent data. Note that to successfully exploit this vulnerability an attacker must have a valid credential. View CVE Details Affected Products Hitachi Energy FACTS Control Platform (FCP) Vendor: Hitachi Energy Product Version: FACTS Control Platform (FCP) version 3.4.0, FACTS Control Platform (FCP) version 3.7.0, FACTS Control Platform (FCP) version 3.8.0, FACTS Control Platform (FCP) version 3.10.0, FACTS Control Platform (FCP) version 3.12.0, FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1 Product Status: known_affected Remediations Mitigation Follow general mitigation factors. For more information see the associated Hitachi Energy security advisory 8DBD000229. Relevant CWE: CWE-943 Improper Neutralization of Special Elements in Data Query Logic Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.9 CRITICAL CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H CVE-2024-3980 The FACTS Control system with GWS allows an authenticated user input to control or influence paths or file names that are used in filesystem operations. If exploited the vulnerability allows the attacker to access or modify system files or other files that are critical to the application. View CVE Details Affected Products Hitachi Energy FACTS Control Platform (FCP) Vendor: Hitachi Energy Product Version: FACTS Control Platform (FCP) version 3.4.0, FACTS Control Platform (FCP) version 3.7.0, FACTS Control Platform (FCP) version 3.8.0, FACTS Control Platform (FCP) version 3.10.0, FACTS Control Platform (FCP) version 3.12.0, FACTS Control Platform (FCP) version 3.14.0, FACTS Control Platform (FCP) version 3.15.0, FACTS Control Platform (FCP) version 4.0.0, FACTS Control Platform (FCP) version 4.0.1, FACTS Control Platform (FCP) version 4.1.0, FACTS Control Platform (FCP) version 4.1.1 Product Status: known_affected Remediations Mitigation Follow general mitigation factors. For more information see the associated Hitachi Energy security advisory 8DBD000229. Rele