Zero-Day
Hitachi Energy TRO600 series products
View CSAF Summary Hitachi Energy is aware of multiple vulnerabilities that affect the TRO600 series product versions listed in this document. These vulnerabilities can be exploited for remote code execution (RCE) to carry out further attacks and disclosure of sensitive informatio
CISA Alerts··3 min read
View CSAF Summary Hitachi Energy is aware of multiple vulnerabilities that affect the TRO600 series product versions listed in this document. These vulnerabilities can be exploited for remote code execution (RCE) to carry out further attacks and disclosure of sensitive information. Please refer to the Recommended Immediate Actions section for information about the mitigation/remediation. The following versions of Hitachi Energy TRO600 series products are affected: TRO600 vers:TRO600/<=9.2.1.6, vers:TRO600/<=9.1.1.0, 9.2.2.1, 9.1.2.0 (CVE-2026-10756, CVE-2026-106087) CVSS Vendor Equipment v3 7.5 Hitachi Energy TRO600 2 Vulnerabilities Improper Restriction of Communication Channel to Intended Endpoints, Missing Authentication for Critical Function Background Critical Infrastructure Sectors: Energy Countries/Areas Deployed: Worldwide Company Headquarters Location: Switzerland Vulnerabilities Expand All + CVE-2026-10756 TRO600 contains a vulnerability that allows an authenticated attacker to bypass network access restrictions and access services intended to be reachable only from localhost. By leveraging port forwarding, an attacker can interact with locally bound ports and services, resulting in unauthorized access to sensitive functionality and confidential information, and causing availability impact. Read More 1 Affected Product TRO600 version 9.2.1.6 and prior Product Status: fixed, known_affected, recommended Remediations Vendor fix Update to version 9.2.2.1 Additional Metrics Relevant CWE: CWE-923 Improper Restriction of Communication Channel to Intended Endpoints CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H 4.0 7.7 HIGH CVSS:4.0/AV:N/AC:H/AT:P/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N View CVE Details CVE-2026-106087 TRO600 contains an arbitrary file read vulnerability. An unauthenticated attacker can exploit this vulnerability to read or download arbitrary files on the affected device, including sensitive configuration files and password data, resulting in the disclosure of sensitive information. Read More 2 Affected Products TRO600 version 9.2.1.6 and prior Product Status: fixed, known_affected, recommended Remediations TRO600 version 9.1.1.0 and prior Product Status: fixed, known_affected, recommended Remediations Vendor fix Fixed in version 9.1.2.0. Update to the latest version 9.2.2.1. Additional Metrics Relevant CWE: CWE-306 Missing Authentication for Critical Function CVSS Version Base Score Base Severity Vector String 3.1 7.5 HIGH CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N 4.0 8.7 HIGH CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N View CVE Details Acknowledgments Hitachi Energy Internal Team reported these vulnerabilities to CISA. Notice The information in this document is subject to change without notice and should not be construed as a commitment by Hitachi Energy. Hitachi Energy provides no warranty, express or implied, including warranties of merchantability and fitness for a particular purpose, for the information contained in this document, and assumes no responsibility for any errors that may appear in this document. In no event shall Hitachi Energy or any of its suppliers be liable for direct, indirect, special, incidental or consequential damages of any nature or kind arising from the use of this document, or from the use of any hardware or software described in this document, even if Hitachi Energy or its suppliers have been advised of the possibility of such damages. This document and parts hereof must not be reproduced or copied without written permission from Hitachi Energy and the contents hereof must not be imparted to a third party nor used for any unauthorized purpose. All rights to registrations and trademarks reside with their respective owners. Support For additional information and support please contact your product provider or Hitachi Energy service organization. For contact information, see https://www.hitachi