Scams
Mira Hormone Monitor, Mira Android App
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access unauthorized health profile information, make changes to health information, cause a denial-of-service condition, disclose session token information, and obtain control of user ac
CISA Alerts··3 min read
View CSAF Summary Successful exploitation of these vulnerabilities could allow an attacker to access unauthorized health profile information, make changes to health information, cause a denial-of-service condition, disclose session token information, and obtain control of user accounts. The following versions of Mira Hormone Monitor, Mira Android App are affected: Mira Monitor Firmware 1.7.1.47 (CVE-2026-66875, CVE-2026-66098, CVE-2026-67558, CVE-2026-67568, CVE-2026-68067, CVE-2026-66340, CVE-2026-64934, CVE-2026-66832) Mira Android App 4.5.15.4 (CVE-2026-66875, CVE-2026-66098, CVE-2026-67558, CVE-2026-67568, CVE-2026-68067, CVE-2026-66340, CVE-2026-64934, CVE-2026-66832) CVSS Vendor Equipment Vulnerabilities v3 9.8 Quanovate Tech Inc. (operating as Mira / Mira Care) Mira Hormone Monitor, Mira Android App Missing Authentication for Critical Function, Authentication Bypass by Spoofing, Use of Hard-coded Credentials, Weak Authentication, Improper Restriction of Excessive Authentication Attempts, Reliance on Untrusted Inputs in a Security Decision, Use of GET Request Method With Sensitive Query Strings Background Critical Infrastructure Sectors: Healthcare and Public Health Countries/Areas Deployed: Worldwide Company Headquarters Location: United States Vulnerabilities Expand All + CVE-2026-66875 In the Mira hormone monitor device firmware v1.7.1.47 build 01070147, a remote unauthenticated attacker within BLE range (approximately 10–30 meters) can silently rebind the device to an attacker-controlled account, extract stored hormone measurements in cleartext, cause a denial-of-service via malformed or undocumented command opcodes, and passively track the user via a static random BLE address that never rotates. View CVE Details Affected Products Mira Hormone Monitor, Mira Android App Vendor: Quanovate Tech Inc. (operating as Mira / Mira Care) Product Version: Quanovate Tech Inc. (operating as Mira / Mira Care) Mira Monitor Firmware: 1.7.1.47, Quanovate Tech Inc. (operating as Mira / Mira Care) Mira Android App: 4.5.15.4 Product Status: known_affected Remediations Mitigation Users should update the Mira app to the latest version iOS v3.5.18 / Android v4.5.18. Firmware v01.07.01.53 is updated via the app when the device is connected. No additional action is required. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 8.8 HIGH CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H 4.0 8.7 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N CVE-2026-66098 The Mira hormone monitor device firmware accepts a 0x01 write from any BLE central without authentication, causing the device to reboot into bootloader mode. An attacker could cause a denial-of-service condition or disrupt ovulation tracking and fertility monitoring workflow. View CVE Details Affected Products Mira Hormone Monitor, Mira Android App Vendor: Quanovate Tech Inc. (operating as Mira / Mira Care) Product Version: Quanovate Tech Inc. (operating as Mira / Mira Care) Mira Monitor Firmware: 1.7.1.47, Quanovate Tech Inc. (operating as Mira / Mira Care) Mira Android App: 4.5.15.4 Product Status: known_affected Remediations Mitigation Users should update the Mira app to the latest version iOS v3.5.18 / Android v4.5.18. Firmware v01.07.01.53 is updated via the app when the device is connected. No additional action is required. Relevant CWE: CWE-306 Missing Authentication for Critical Function Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H 4.0 7.1 HIGH CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N CVE-2026-67558 The Mira Android companion app v4.5.15.4 identifies the paired Mira hormone analyzer by performing a substring match against the BLE advertisement name only, with no cryptographic peripheral authentication, MAC allowlist, or bonded-identity check. An attacker could capture live session token informat