View CSAF Summary SIDIS Secured SmartPlug before V7.26.0310 is affected by multiple vulnerabilities in the components OpenSSL, OpenSSH, and several other packages as described below. Siemens has released a new version of SIDIS Secured SmartPlug and recommends to update to the lat
CISA Alerts··4 мин чтения
View CSAF Summary SIDIS Secured SmartPlug before V7.26.0310 is affected by multiple vulnerabilities in the components OpenSSL, OpenSSH, and several other packages as described below. Siemens has released a new version of SIDIS Secured SmartPlug and recommends to update to the latest version. The following versions of Siemens SIDIS Secured SmartPlug are affected: SIDIS Secured SmartPlug vers:intdot/<7.26.0310 CVSS Vendor Equipment Vulnerabilities v3 9.8 Siemens Siemens SIDIS Secured SmartPlug Improper Enforcement of Message Integrity During Transmission in a Communication Channel, Reusing a Nonce, Key Pair in Encryption, Out-of-bounds Write, Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Integer Overflow or Wraparound, Out-of-bounds Read, Covert Timing Channel, Detection of Error Condition Without Action, Incorrect Authorization Background Critical Infrastructure Sectors: Critical Manufacturing Countries/Areas Deployed: Worldwide Company Headquarters Location: Germany Vulnerabilities Expand All + CVE-2022-23303 The implementations of SAE in hostapd before 2.10 and wpa_supplicant before 2.10 are vulnerable to side channel attacks as a result of cache access patterns. NOTE: this issue exists because of an incomplete fix for CVE-2019-9494. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 9.8 CRITICAL CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H CVE-2022-23304 The implementations of EAP-pwd in hostapd before 2.10 and wpa_supplicant before 2.10 are vulnerable to side-channel attacks as a result of cache access patterns. NOTE: this issue exists because of an incomplete fix for CVE-2019-9495. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-924 Improper Enforcement of Message Integrity During Transmission in a Communication Channel Metrics CVSS Version Base Score Base Severity Vector String 3.1 7 HIGH CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H CVE-2022-37660 In hostapd 2.10 and earlier, the PKEX code remains active even after a successful PKEX association. An attacker that successfully bootstrapped public keys with another entity using PKEX in the past, will be able to subvert a future bootstrapping by passively observing public keys, re-using the encrypting element Qi and subtracting it from the captured message M (X = M - Qi). This will result in the public ephemeral key X; the only element required to subvert the PKEX association. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-323 Reusing a Nonce, Key Pair in Encryption Metrics CVSS Version Base Score Base Severity Vector String 3.1 6.5 MEDIUM CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N CVE-2022-48174 There is a stack overflow vulnerability in ash.c:6030 in busybox before 1.35. In the environment of Internet of Vehicles, this vulnerability can be executed from command to arbitrary code execution. View CVE Details Affected Products Siemens SIDIS Secured SmartPlug Vendor: Siemens Product Version: SIDIS Secured SmartPlug < V7.26.0310 Product Status: known_affected Remediations Vendor fix Update to V7.26.0310 or later version Relevant CWE: CWE-787 Out-of-bounds Write Metrics CVSS Version Base Score Base Severity Vector String 3.1 7.8 HIGH CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H CVE-2025-5222 A stack buffer overf